Gate power consuption measurement #97
Loading…
Reference in a new issue
No description provided.
Delete branch "%!s()"
Deleting a branch is permanent. Although the deleted branch may continue to exist for a short time before it actually gets removed, it CANNOT be undone in most cases. Continue?
https://mauser.pt/095-7674/dfrobot-sen0291-modulo-sensor-de-corrente-tensao-e-potencia-26v-8a
Setup: Put the INA219 in the battery’s positive lead ( board/charger B+ → VIN+; VIN− → cell + ). Connect it to the spare ESP32 logger and record timestamped battery voltage and signed current.
Test 1 — Battery-only baseline: Disconnect PoE, leave the battery connected, and run the normal ESP32 workload. Log a representative operating cycle. This measures how much current the board draws from the battery and how the battery voltage behaves under that load. With the stated sensor orientation, current should be negative.
Test 2 — PoE with battery connected: Connect PoE while leaving the battery connected. Run the same workload and log for a representative cycle. This measures the battery’s net current while PoE is present: positive means the battery is charging, negative means it is still supplying some power, and near zero means little net battery current. Start this test with the battery not nearly full, to reduce charge-taper effects.
Compare: For each test, report the average and range of battery current and voltage. These tests characterize battery behavior; they do not measure total PoE input power or estimate state of charge.